防火板隔墙应用性能分析

1.防火板材:一般情况下建议用6mm厚度以上的玻镁板作隔墙板。www.4546.com
1: recommended for fireproof board partition wall board with magnesium plate thickness more than 6mm under normal circumstances.
2.配件:6mm以上的板材固定在框架龙骨上,要用3.5200mm的沉头螺钉固定,钉头低于板面0.5mm,以便保证饰面平整。
2 parts: more than 6mm plate fixed on the keel frame to 3.5200mm countersunk head screws, nail head lower than 0.5mm board, so as to ensure a smooth finish.
3.安装:开始安装时,必须标好龙骨的准确位置,并作好记号。竖龙骨中心距离为450-600mm,墙体的连接处和门窗两侧安装时要装附加龙骨,如墙体高度大于2440mm时,须在板材连接处加装支撑龙骨。
3 installation: start the installation, accurate location must be marked keel, and mark. Vertical keel center distance is 450-600mm, the wall connected at both sides and the installation of doors and windows to hold additional keel, such as the wall height is more than 2440mm, to be installed in the joint plate support keel.
4.板距:相临板材之间留缝距4-6mm,板材与地面之间必须留有5mm的间隙,螺钉安装中心距为150mm,距板边10mm,距离板角30mm。
4: the board from adjacent seam between the plates from the 4-6mm, must have a 5mm gap between the plate and the ground screw mounting center for 150mm, distance from the edge of 10mm, the distance angle 30mm.
5.吊挂:卫生间或厨房间等吊挂重物处,必须用木板或龙骨加固,以免板材受到破坏。
5: the bathroom or kitchen hanging between the hanging weight, must be reinforced with wood or keel, so as not to damage the plate.
6.接缝处理:在安装时板材与板材留有间隙4-6mm,用107胶水或强力胶调匀后用刮刀涂抹板材及缝隙处,然后用纸带或风格带粘贴压平。
6. Joint treatment: installed in the sheet and plate left a gap is 4-6mm, 107 glue or glue and mix thoroughly after use with a scraper smearing plate and the gap, and then use tape or style tape applanation.
www.4546.com
7.涂料装饰:可以用喷涂、刷涂或滚涂,但刷涂时必须参看涂料的有关说明。
7: you can use paint spray, brush and roller, but must see that the brush paint.
8.装饰面贴瓷砖:在浴室、卫生间、厨房、地下室等潮湿区域安装时,如需在板面贴瓷砖龙骨之间的距离必须缩短到400mm。墙体每隔三块板(约3.6mm左右)必须留有一条伸缩缝。
8. Decorative surface Tiling: in the bathroom, toilet, kitchen, basement, etc. wet installation area, such as at the surface of the plate affixed tiles between the keel distance must be shortened to 400mm. The wall every three pieces (about 3.6mm) must have a joint.
9.隔音墙体:如需墙体有较高的隔音效果,必须要求墙体和板材结合紧密密闭,再向空墙内填充矿棉,如龙骨两面采用两种不同厚度的板时,隔间效果更佳。
9. Sound insulation wall: for high wall with sound insulation effect must be tightly closed wall and plate requirements, to within the walls of the air filling mineral wool, such as using two different thickness of plate on both sides of the keel compartments, a better effect.
10.抗冲击墙体:建议您选用8mm以上的防火板或加一层板,第二张板须用长一些的螺丝钉加固。这种方法可增强抗冲击、隔热、隔音效果和防火性能。
10 anti impact wall: it is recommended that you choose to use 8mm above the fire board or plus a layer of plywood, second plates with a long length of some of the screws. This method can enhance the impact resistance, heat insulation, sound insulation and fire resistance performance.

<<